  Datasheet File OCR Text:
  btel5000 / ptul5000 series precision very low differential pressure transmitters 1/5 e / 11094 / a www.first-sensor.com www.sensortechnics.com features 1 to 10 mbar, 1 to 10 inh 2 o differential pressure 1...6 v or 4...20 ma output precision temperature compensated and calibrated rugged aluminium housing female 1/8" bsp and 1/8" npt fittings specifications 12 maximum ratings supply voltage 11 12...32 v output current btel/ptul5...d1... source 20 ma sink 10 ma btel/ptul5...d4... 30 ma temperature limits storage -40...100c operating -25...85c compensated 0 ...50c proof pressure 2 btel/ptul5...01d... 250 mbar / 100 "h 2 o btel/ptul5...02d... 250 mbar / 100 "h 2 o all others 350 mbar / 150 "h 2 o pressure at any port 3 btel/ptul5...01d... 500 mbar / 200 "h 2 o btel/ptul5...02d... 500 mbar / 200 "h 2 o all others 750 mbar / 300 "h 2 o electrical connection 4...20 ma output version 1...6 v output version 2 4 3 vout sensor case -vs +vs 1 gnd v 12 to 32 v case -vs sensor +vs gnd 3 4 r l 12 to 32 v 1 v media compatibility pressure inlet: non-corrosive, non-ionic working fluids such as air, dry gases and the like housing: aluminium, protection class ip 67 (according to din en 60529, nema 6) 1
btel5000 / ptul5000 series precision very low differential pressure transmitters 2/5 e / 11094 / a www.first-sensor.com www.sensortechnics.com common performance characteristics 9 s c i t s i r e t c a r a h c. n i m. p y t. x a mt i n u y t i v i t i s n e s n o i t i s o p 5 . 0g / o s f % s i s e r e t s y h d n a y t i r a e n i l - n o n 4 1 . 0 5 2 . 0 o s f % ) z h k 1 < f < 0 ( e s i o n t u p t u o 4 0 . 0 y t i l i b a t s m r e t g n o l 5 . . . d 1 0 . . . 5 l u t p / l e t b5 . 0 s r e h t o l l a2 . 0 ) c 0 5 o t 0 ( s t c e f f e l a m r e h t 6 t e s f f o. . . d 1 0 . . . 5 l e t b8 0 . 0 6 1 . 0 c / o s f % / . . . d 2 0 . . . 5 l e t b . . . d 1 0 . . . 5 l u t p 4 0 . 0 0 1 . 0 s r e h t o l l a2 0 . 0 6 0 . 0 n a p s4 0 . 0 8 0 . 0 ) % 0 9 o t 0 1 ( e m i t e s n o p s e r 1s m 1...6 v output versions (v s = 15 v, t amb = 25c, r l > 100 k ? , com. mode pressure = 0) 4...20 ma output versions (v s = 15 v, t amb = 25c, r l = 100 ? , com. mode pressure = 0) s c i t s i r e t c a r a h c. n i m. p y t. x a mt i n u t e s f f o e r u s s e r p o r e z 7 . . . 1 d . . . 0 5 l u t p / l e t b . . . 1 d . . . p 5 l u t p / l e t b 9 . 0 4 . 3 0 . 1 5 . 3 1 . 1 6 . 3 v n a p s e l a c s l l u f 8 . . . 1 d . . . 0 5 l u t p / l e t b . . . 1 d . . . p 5 l u t p / l e t b 9 . 4 4 . 2 0 . 5 5 . 2 1 . 5 6 . 2 t u p t u o e l a c s l l u f 0 . 6 e c n a d e p m i t u p t u o 0 5 ? n o i t c e j e r y l p p u s r e w o pt e s f f o n a p s 5 0 . 0 3 0 . 0 v / o s f % n o i t p m u s n o c r e w o p 0 6w m s c i t s i r e t c a r a h c. n i m. p y t. x a mt i n u t e s f f o e r u s s e r p o r e z 7 . . . 4 d . . . 0 5 l u t p / l e t b . . . 4 d . . . p 5 l u t p / l e t b 9 . 3 9 . 1 1 0 . 4 0 . 2 1 1 . 4 1 . 2 1 a m n a p s e l a c s l l u f 8 . . . 4 d . . . 0 5 l u t p / l e t b . . . 4 d . . . p 5 l u t p / l e t b 9 . 5 1 9 . 7 0 . 6 1 0 . 8 1 . 6 1 1 . 8 t u p t u o e l a c s l l u f 0 . 0 2 e c n a d e p m i t u p t u o 1 . 0 ? n o i t c e j e r y l p p u s r e w o pt e s f f o n a p s 5 0 . 0 3 0 . 0 v / o s f % i ( n o i t p m u s n o c r e w o p l ) a m 0 2 =0 6 2w m individual performance characteristics 9
btel5000 / ptul5000 series precision very low differential pressure transmitters 3/5 e / 11094 / a www.first-sensor.com www.sensortechnics.com specification notes: 1. ip 67 protection for btel/ptul5... a is given with locked connector only. 2. proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 3. this is the highest pressure which can be applied to any port at any time. at the same time the differential pressure between the ports h and l must not exceed the maximum proof pressure. 4. non-linearity refers to the b est s traight l ine fit measured for offset, full scale span and 1/2 full scale span. 5. long term stability is the change in output after one year or 1 million pressure cycles. 6. thermal effects tested and guaranteed from 0...50 c relative to 25. all specifications shown are relative to 25c. 7. calibrated after minimum 3 minutes warm-up time. 8. full scale span is the algebraic difference between the positive full scale output and zero pressure offset. 9. higher pressure applied to port h. 10. test are in accordance with en 61000-6-2. 11. the minimum supply voltage is directly proportional to the load resistance seen by the transmitter. for more details see the load limitation diagram. 12. ce-labelling is in accordance with 2004/108/ec. load limitation 4...20 ma output version operating 0 200 400 10 20 1000 600 800 ohm 1200 30 vsupply v range electromagnetic capability 10 s n o i t i d n o c t s e tn o i r e t i r c e c n e r e f r e t n i y c n e u q e r f o i d a r , d e t a i d a r ) i f r ( y t i n u m m i d l e i f c i t e n g a m o r t c e l e : 3 - 4 - 0 0 0 1 6 n ez h m 0 0 0 1 o t 0 8 , m / v 0 1 ) z h k 1 ( c m a % 0 8 ao s f % 1 < / t n e i s n a r t t s a f l a c i r t c e l e ) t f e ( y t i n u m m i t s r u b : 4 - 4 - 0 0 0 1 6 n ev k 2 bo s f % 1 < y t i n u m m i e g r a h c s i d c i t a t s o r t c e l e ) d s e ( t s e t : 2 - 4 - 0 0 0 1 6 n ee g r a h c s i d t c a t n o c , v k 4 e g r a h c s i d r i a , v k 8 bo s f % 1 < s e c n a b r u t s i d d e t c u d n o c o t y t i n u m m i s d l e i f y c n e u q e r f - o i d a r y b d e c u d n i : 6 - 4 - 0 0 0 1 6 n ez h m 0 8 o t 5 1 . 0 ) z h k 1 ( c m a % 0 8 , v 0 1 ao s f % 1 <
btel5000 / ptul5000 series precision very low differential pressure transmitters 4/5 e / 11094 / a www.first-sensor.com www.sensortechnics.com mass: typ. 220 g dimensions in mm (inches) outline drawing connector version electrical connection pin 1 2 3 4 connection 4...20 ma output +vs nc case -vs 1...6 v output +vs vout case -vs electrical connection bare brown white green yellow 1...6 v output case/shield +vs nc vout -vs connection 4...20 ma output case/shield +vs nc nc -vs 72.0 (2.84) nom 86.0 (3.39) 40.0 (1.58) 20.0 (0.79) 2 x m5 (unc 10-24) bte.../pte...: 2 x 1/8" bsp ptu...: 2 x 1/8" npt 8.0 (0.31) min. 13.5 diam. (0.53) 8.0 (0.31) min. m12 x 1 (0.47) 1 2 4 3 9.0 (0.35) mating plug h: high pressure port l: low pressure port 90.0 (3.54) 72.0 (2.84) 40.0 (1.58) 13.5 diam. (0.53) 1 m (3.3 ft) shielded cable 4 x 0.25 mm2 (awg24) 8.0 (0.31) min. 8.0 (0.31) min. 9.0 (0.35) h: high pressure port l: low pressure port 20.0 (0.79) 2 x m5 (unc 10-24) bte.../pte...: 2 x 1/8" bsp ptu...: 2 x 1/8" npt cable version mass: typ. 170 g dimensions in mm (inches)
btel5000 / ptul5000 series precision very low differential pressure transmitters 5/5 e / 11094 / a www.first-sensor.com www.sensortechnics.com 36.5 ? 20 m12 x 1 nom 60 nom 2 m btel/ptul 5xxx d x x ordering information calibration btel: calibration in mbar ptul: calibration in inh 2 o pressure range btel5000 series ptul5000 series 001: 0...1 mbar 001: 0...1 inh 2 o p01: -1...+1 mbar p01: -1...+1 inh 2 o 002: 0...2 mbar 002: 0...2 inh 2 o p02: -2...+2 mbar p02: -2...+2 inh 2 o 005: 0...5 mbar 005: 0...5 inh 2 o p05: -5...+5 mbar p05: -5...+5 inh 2 o 010: 0...10 mbar 010: 0...10 inh 2 o p10: -10...+10 mbar p10: -10...+10 inh 2 o note: 0...1 mbar devices not available with 1...6 v output signal electrical connection a: connector version c: cable version output signal 1: 1...6 v 4: 4...20 ma differential pressure recommended cable/connector accessory for connector version order number zk000101 , other cable lengths on special request flying lead end brown green white + shield yellow pin 1 2 3 4 pin connection dimensions in mm included in delivery! other pressure ranges and options are widely available. please contact first sensor. first sensor reserves the right to make changes to any products herein. first sensor does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others.


▲Up To Search▲   

 
Price & Availability of PTUL5010D1C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X